Firejet 4C - DHCP Server setup

Firejet 4C - DHCP Server setup

First check if the navigator applications are showing a connection to the Duraflex module. If the "Press Controller" is showing "Not Connected" then open a new command prompt and ping 192.168.100.200
If there is no response, then open up the DHCPSRV2 folder on the desktop and open the wizard. If the 1G connection shows "Disabled" than reset the connection by following the directions below.

1. Open "dhcpwiz.exe" file in the "DHCPSRV2" folder on the desktop
2. Select "Next" then select the 1G connection and hit "Next"
3. Click "HTTP (Web Server)" and hit "Next"
4. Change the IP-Pool to 192.168.100.200-200 and deselect "Trace" then click "DHCP Options" button
5. Enter "DuraFlex" in the "Domain Name:" field and hit "Ok" then hit "Next"
6. Check the "Overwrite existing file" box and click the "Write INI file" button
7. In the "DHCPSRV2" folder, open the "dhcpsrv.ini" file and add "PORT_80=8080" to the last line under the "Settings" portion of the file the save and close the file
8. Now click "Install" if the field is available or "Start"
9. Open another command prompt window and enter "ping 192.168.100.200" and you should see the connection reestablished
    • Related Articles

    • Duraflex Pump2 Error

      If you see the error in your DFE or in the press controller do the following: Close Navigator Client Close Navigator Server (Wait for application to close completely before next step) Shut down power to the duraflex cabinet at the power switch (Green ...
    • Data Underrun - Firejet 4C - Reinstall Drivers

      If you have an error being displayed in the press controller or the DFE stating "Data Underrun" please follow the steps below to fix the issue. 1. Right click the windows start menu and select the "Device Manager". 2. Expand the "Network Adapters" ...
    • Firejet Domain Account - Xitron Reinstallation

      Exact Steps: 1. Used Backrest to create a backup 2. Manually made a copy of the entire Navigator folder 3. Made a manual copy of the APPDATA/Xitron folder 4. Made a manual copy of the PROGRAMDATA/Xiton folder 5. Ran the Installer ...